Which one is having the highest value of fouling factor?

Which one is having the highest value of fouling factor? Explanation: Fouling factor for engine exhaust is 0.002 while that of industrial liquids, fuel oil and turbine exhaust are 0.0002, 0.0010 and 0.0002 respectively.

What is a membrane module?

Membrane module is the way the membrane is arranged into devices and hardware to separate the feed stream into permeate and retentate streams.

What causes clinker formation in boiler?

Clinkers resemble volcanic ash and lava. They occur in the high-temperature furnace area of the boiler. The most common cause of clinker in a boiler is inferior fuel sources. Low-quality coal, such as lignite, contains a higher concentration of water and minerals including pyrite, iron, calcium, sodium and potassium.

What are the causes of fouling?

Types of foulingChemical fouling, or scaling, occurs when chemical changes within the fluid cause a fouling layer to be deposited onto the tube surface. … Biological fouling is caused by the growth of organisms, such as algae, within the fluid that deposit onto the surfaces of the heat exchanger.More items…•

How do you find the fouling factor?

Typical Fouling FactorsAlcohol vapors : Rd = 0.00009 (m2K/W)Boiler feed water, treated above 325 K : Rd = 0.0002 (m2K/W)Fuel oil : Rd = 0.0009 (m2K/W)Industrial air : Rd = 0.0004 (m2K/W)Quenching oil : Rd = 0.0007 (m2K/W)Refrigerating liquid : Rd = 0.0002 (m2K/W)Seawater below 325 K : Rd = 0.00009 (m2K/W)More items…

What is fouling in water treatment?

Fouling occurs when contaminants collect on the surface or in the pores of a filtration membrane. Foulants restrict water flow through the membrane, resulting in several consequences such as higher hydraulic resistance, greater energy consumption, and even damage to the membrane and other system components.

What is the fouling factor of chiller?

improve operating efficiency of chillers. From these results, a field fouling allowance of 0.0001 or 1.0 x 10-4 hr · ft2°F/Btu [1.8 x 10-5 m2 · °C/W] appears to be more appropriate for evaporators and is the recommendation of this guideline.

What is overall heat transfer coefficient?

The overall heat transfer coefficient, or U-value, refers to how well heat is conducted through over a series of resistant mediums. Its units are the W/(m2°C) [Btu/(hr-ft2°F)].

When effectiveness and NTU method is used instead of lmtd method?

In heat exchanger analysis, if the fluid inlet and outlet temperatures are specified or can be determined by simple energy balance, the LMTD method can be used; but when these temperatures are not available The NTU or The Effectiveness method is used.

What is iron fouling?

Iron fouling is a serious problem in water softeners. Colorless-reduced iron will be removed by a water softener, but once the water is exposed to air or chlorine, red-oxidized iron will foul the softener. Preventive measures should be taken to filter out any red-oxidized iron before it enters the water softener.

What do you mean by fouling?

Fouling is the accumulation of unwanted material on solid surfaces. The fouling materials can consist of either living organisms (biofouling) or a non-living substance (inorganic or organic). … Of the two, micro fouling is the one that is usually more difficult to prevent and therefore more important.

How do I stop membrane fouling?

Select a membrane with an optimum pore size to result in good separation performance as well as optimized permeate flux. Optimize the operating conditions. This includes increasing transmembrane pressure to maximize flux without introducing more fouling potential.

How does fouling factor affect heat transfer?

The deposition of any undesired material on heat transfer surfaces is called fouling. … Fouling increases the overall thermal resistance and lowers the overall heat transfer coefficient of heat exchangers. Fouling also impedes fluid flow, accelerates corrosion and increases pressure drop across heat exchangers.

What is ash softening temperature?

%, the softening temperature becomes greater than 1400°C. The CaO content in the coal ash, which is a basic oxide with a melting point of 2610°C is usually formed as a result of the decomposition of CaCO3 (calcite) and CaSO4 (anhydrite), etc., which exist in low-rank coals (Zhang, 2014).

What is the difference between slagging and fouling?

The word “slagging” is usually used to describe slagging in the furnace, whereas fouling is generally used to describe cinders or ash that have carried over into the convection pass and created flow obstructions due to the deposition.

What is the unit of fouling factor?

The fouling factor, Rf, as well as the deposition rate, d, and the removal rate, r, can be expressed in the units of thermal resistance as m2·K/W or in the units of the rate of thickness change as m/s or units of mass change as kg/ m2· s.

What is the scaling?

Definition: Scaling is the procedure of measuring and assigning the objects to the numbers according to the specified rules. In other words, the process of locating the measured objects on the continuum, a continuous sequence of numbers to which the objects are assigned is called as scaling.

What are the economic penalties for fouling?

The penalty of fouling is ship speed loss at constant power, or, power increase at constant speed, or, consequentially, an economic penalty due to increased fuel consumption and scheduling penal- ties and other delays.

What is effective heat exchanger?

The effectiveness (ϵ) of a heat exchanger is defined as the ratio of the actual heat transfer to the maximum possible heat transfer.

What is fouling in pipes?

Fouling stands in technical applications, for the unwanted growth or formation of deposits on surfaces. Fouling occurs on the inside of pipes, machines or heat exchangers. … These deposits reduce the cross-section of the pipe and thus impede the flow and heat transfer.

What is fouling and scaling?

Scaling is a type of fouling caused by inorganic salts in the water circuit of the heat exchanger. It increases the pressure drop and insulates the heat transfer surface, thus preventing efficient heat transfer.

What is scale in water treatment?

What is Water Scale? Water Scale is a coating or precipitate deposited on surfaces that are in contact with hard water. … When water is heated or evaporation takes place, scale minerals precipitate layers of rocklike deposits inside pipes, water heaters, equipment, and on fixtures and glassware.

How do you remove iron from bore water naturally?

Aeration may be the best and cheapest option to remove iron from water. The iron remains in the dissolved ferric state in the absence of oxygen or when the water is in the groundwater table.